hlavné referencie
Page Image

2014-2015

Montáž CFB kotla v Dunaujvaros

 

Hamburger Hungária Erömü Kft, Hungary

 

Parameters: 158MWt steam, 42MWe, 11,3Mpa, 520°C

 

Installation complete new biomass/coal fired boiler, boiler internal piping, air and flue gas ducts, air and flue gas fans.

 

Materials: X10CrMoVNb9-1, 13CrMo4-5, 10CrMo9-10, 16Mo3, P265GH, Piping from SS

Total weight approx. 1 900 tons

 

Percentage of participation in project implementation: 100%

 

Manpower on site: Maximum 100, Average 80

 

Valmet Power Oy, Lentokentänkatu 11, 33101 Tampere, Finland